martechsystems.com
Martech Systems
http://www.martechsystems.com/faqs.html
How should I use a consultant? What is the process to retain a consultant? Can you name the 8 basic rules when using a consultant? How should I use a consultant? To address a specific issue or solve a specific problem, with measurable results or deliverables. To support staff resources as a source of technical information and objective conclusions. What is the process to retain a consultant? Initial consultation to define scope of work and determine suitability of the consultant. Visit our new blog.
martechsystems.com
Martech Systems
http://www.martechsystems.com/optimization.html
Troubleshooting utility system operating inefficiencies and implementing corrective action. Cracked inlet lateral in strong acid cation demineralizer caused poor distribution of flow and short runs. Improper dosage and insufficient reaction time for coagulant resulted in poor quality clarified water, short service cycle for downstream filters and excessively high filter backwash frequency. Technical experts will be required to maintain the reliability and availability of your systems.
martechsystems.com
Martech Systems
http://www.martechsystems.com/failureinvest.html
Determining the root causes of failure to prevent additional lost opportunity costs. Examples of our failure investigations. Cat Cooler (waste heat boiler) failure due to under-deposit corrosion caused by a lack of conformance to specifications for boiler water chemistry. - download PDF case history. Debutanizer failure due to under-deposit corrosion caused by poor control of chemical treatment program and subsequent deactivation of copper corrosion inhibitor. - download PDF case history.
martechsystems.com
Martech Systems
http://www.martechsystems.com/articles.html
Is your cold lime softener effective? Chemical Engineering Progress (AICHE), Dec 2007. Read about Cold Lime Softening, excerpted from Chapter 2 of “Operating Practices for Industrial Water Management, Influent Water Systems”. By Loraine Huchler, P.E., CMC, published September 2007 by Gulf Publishing, Inc. - download PDF. 8220;Select the Best Boiler-Water Chemical Treatment Program,”. Chemical Engineering Progress (AICHE), Aug 1998 - visit www.aiche.org. Visit our new blog. Click here to view our blog.
martechsystems.com
Martech Systems
http://www.martechsystems.com/specsupplier.html
Specifications and Supplier Selection. Reducing the cost of water treatment chemicals and improving the quality of service. Are you receiving value from your water treatment chemical supplier? Download PDF case history. Find out what our client says! We have also created specification documents to assist owners of commercial and institutional facilities with the procurement of replacement cooling towers and boilers. Website design by alex krail designs.
martechsystems.com
Martech Systems
http://www.martechsystems.com/expwitness.html
Providing clients with expert analysis and testimony in trade secret, patent infringement and equipment failure litigation. Providing expert witness testimony requires specific in-depth knowledge, a capability to communicate complex technical ideas to non-technical individuals and an ability to work in stressful situations. Our principal has experience as an expert witness providing depositions and testimony. Website design by alex krail designs.
martechsystems.com
Martech Systems
http://www.martechsystems.com/managedcare.html
Oversight of Water-Related Utility Systems -. Managed care of all your water systems! We review your influent, boiler, cooling and wastewater systems at each site to maximize availability and reliability of these assets. We ensure the consistency of the water treatment programs at all your plant sites while minimizing your operating and maintenance costs. Annual System Audits with Energy Balance Analysis. Technical Oversight of Current Chemical Suppliers. Alternative Supplier Bid Evaluation. Have your ow...
martechsystems.com
Martech Systems
http://www.martechsystems.com/techpapers.html
8220;Non-chemical Water Treatment Systems: Histories, Principles and Literature Review,”. International Water Conference (IWC), Pittsburgh, PA, Oct 2002 - download PDF. 8220;Reduce Project Costs Using Packed Bed Demineralizers,”. 33rd Pulp and Paper Annual Meeting (Joint TAPPI/ABTCP), São Paulo, Brazil, Oct 2000 - download PDF. 8220;Managing Reboiler Steam-side Operation Improves Equipment Reliability and Steam Quality,”. 8220;Keys to On-Line Monitoring in Steam Generating Systems,”. Visit our new blog.
martechsystems.com
Martech Systems
http://www.martechsystems.com/columns.html
Understanding microbiologically influenced corrosion. Hydrocarbon Processing, May 2005. How to inspect the waterside of a fired boiler. Hydrocarbon Processing, February 2005. Should you install an online hardness analyzer? Hydrocarbon Processing, November 2004. For more HP In Water Management Columns. Visit www.hydrocarbonprocessing.com. Visit our new blog. Click here to view our blog. Operating Practices for Industrial Water Management: Influent Water Systems. By visiting our books page.
martechsystems.com
Martech Systems
http://www.martechsystems.com/audits.html
Allowing utility managers to reduce the risk of failure and minimize operating costs. Are your operators properly monitoring your water-based utility systems to maximize efficiency and minimize risk of failure? Or are you waiting for a system failure to measure the current system reliability? How does your incumbent water treatment supplier compare to industry standards? System reliability - download PDF case history. Conformance of chemical treatment and monitoring program to industry standards. We have...