nmr.chem.wsu.edu nmr.chem.wsu.edu

nmr.chem.wsu.edu

Center for NMR Spectroscopy: Introduction

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. The WSU Center for NMR Spectroscopy is a central University facility that provides access to state-of-the-art NMR instrumentation. It is administered by the College of Sciences. And its equipment has been funded by grants from the National Institutes of Health. The National Science Foundation. The Battelle Memorial Institute. And the Murdock Charitable Trust.

http://nmr.chem.wsu.edu/

WEBSITE DETAILS
SEO
PAGES
SIMILAR SITES

TRAFFIC RANK FOR NMR.CHEM.WSU.EDU

TODAY'S RATING

>1,000,000

TRAFFIC RANK - AVERAGE PER MONTH

BEST MONTH

April

AVERAGE PER DAY Of THE WEEK

HIGHEST TRAFFIC ON

Wednesday

TRAFFIC BY CITY

CUSTOMER REVIEWS

Average Rating: 3.2 out of 5 with 5 reviews
5 star
0
4 star
3
3 star
1
2 star
0
1 star
1

Hey there! Start your review of nmr.chem.wsu.edu

AVERAGE USER RATING

Write a Review

WEBSITE PREVIEW

Desktop Preview Tablet Preview Mobile Preview

LOAD TIME

0.2 seconds

FAVICON PREVIEW

  • nmr.chem.wsu.edu

    16x16

CONTACTS AT NMR.CHEM.WSU.EDU

Login

TO VIEW CONTACTS

Remove Contacts

FOR PRIVACY ISSUES

CONTENT

SCORE

6.2

PAGE TITLE
Center for NMR Spectroscopy: Introduction | nmr.chem.wsu.edu Reviews
<META>
DESCRIPTION
Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. The WSU Center for NMR Spectroscopy is a central University facility that provides access to state-of-the-art NMR instrumentation. It is administered by the College of Sciences. And its equipment has been funded by grants from the National Institutes of Health. The National Science Foundation. The Battelle Memorial Institute. And the Murdock Charitable Trust.
<META>
KEYWORDS
1 WSU
2 Washington State
3 Washington State University
4
5 coupons
6 reviews
7 scam
8 fraud
9 hoax
10 genuine
CONTENT
Page content here
KEYWORDS ON
PAGE
office of research,instruments,varian inova 500,varian vnmrs 600,research projects,contacts,nmrc users,new user account,sample request,experiments,manuals and theory,citation instructions,rules and regulations,advanced training,reservation rules,news
SERVER
Microsoft-IIS/10.0
POWERED BY
ASP.NET
CONTENT-TYPE
iso-8859-1
GOOGLE PREVIEW

Center for NMR Spectroscopy: Introduction | nmr.chem.wsu.edu Reviews

https://nmr.chem.wsu.edu

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. The WSU Center for NMR Spectroscopy is a central University facility that provides access to state-of-the-art NMR instrumentation. It is administered by the College of Sciences. And its equipment has been funded by grants from the National Institutes of Health. The National Science Foundation. The Battelle Memorial Institute. And the Murdock Charitable Trust.

INTERNAL PAGES

nmr.chem.wsu.edu nmr.chem.wsu.edu
1

Center for NMR Spectroscopy: Varian Inova 500

http://nmr.chem.wsu.edu/instruments/inova500

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. Oxford 11.75T, 51 mm magent. Oxford 28 gradient shim set. 4 channel console, 1 full band channel and 3 broadband channels with waveform generators on each channel. Triaxial Pulsed Field Gradient amplifier. Deuterium gradient shimming and decoupling switches. Nalorac H{CN }Triple Resonance probe with Z-axis PFG. Nalorac H{CPN} Quad Resonance probe with XYZ-axis PFG.

2

Center for NMR Spectroscopy: Overview of the Console

http://nmr.chem.wsu.edu/tutorials/basics/overview

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. Overview of the Console. A typical arrangement of such components can be seen in the stylized console cartoon found below:. The Acquisition System or digital cardcage can be further represented by the following block diagram:. The active switching mechanism for a high power pulse going into the probe is shown in the following diagram:. The converse arrangement wh...

3

Center for NMR Spectroscopy: Varian Vx 300

http://nmr.chem.wsu.edu/instruments/vx300

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. Varian Mercury Vx 300. Bruker 7.05T, 54 mm bore magnet. Broadbanded 2 channel console. Nalorac 4-nucleus Plus 5mm probe, 1H-19F-13C-31P or 1H-X where X is tunable from 30 to 150 MHz. Modified Bruker Indirect detection probe, 1H-X where X is tunable over the range of 14 to 125 MHz.

4

Center for NMR Spectroscopy: Experiments

http://nmr.chem.wsu.edu/nmrcusers/experiments

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. PO Box 646595, Washington State University, Pullman WA 99164-6525, 509-335-5585, Contact Us.

5

Center for NMR Spectroscopy: Varian VNMRS 600

http://nmr.chem.wsu.edu/instruments/vnmrs600

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. Varian VNMRS 600 (Liquids). Oxford 14.1T 51mm bore maget. 4 channel console, 1 high band, 3 low band. Varian 40 channel shim set. Z-axis pulsed field gradients. 5 mm triple resonance probe, 1H detect {13C,15N} decouple. 5 mm broadband probe, 15N to 31P tuning range (60 to 250 MHz).

UPGRADE TO PREMIUM TO VIEW 15 MORE

TOTAL PAGES IN THIS WEBSITE

20

LINKS TO THIS WEBSITE

molecular.biosciences.wsu.edu molecular.biosciences.wsu.edu

SMB Facilities

http://molecular.biosciences.wsu.edu/facilities

Washington State University is engaged in a major expansion in the field of molecular and materials sciences. Consequently, the University's extensive and modern facilities for research in the chemical and biochemical sciences are continually improving. Major facilities at the School of Molecular Biosciences include:. Center for Reproductive Biology (CRB). Center for NMR Spectroscopy. Laboratory for Biotechnology and Bioanalysis. Biomolecular X-Ray Crystallography Center (BXCC). The University's modern s...

smb.wsu.edu smb.wsu.edu

SMB Facilities

http://www.smb.wsu.edu/facilities

Washington State University is engaged in a major expansion in the field of molecular and materials sciences. Consequently, the University's extensive and modern facilities for research in the chemical and biochemical sciences are continually improving. Major facilities at the School of Molecular Biosciences include:. Center for Reproductive Biology (CRB). Center for NMR Spectroscopy. Laboratory for Biotechnology and Bioanalysis. Biomolecular X-Ray Crystallography Center (BXCC). The University's modern s...

UPGRADE TO PREMIUM TO VIEW 2 MORE

TOTAL LINKS TO THIS WEBSITE

4

OTHER SITES

nmr.chem.ucsb.edu nmr.chem.ucsb.edu

UCSB Chem and Biochem NMR Facility

He Is Your Friend. The NMR Facility at the Department of Chemistry and Biochemistry. Is home to four solution-state NMR spectrometers: a Varian Unity Inova 400 MHz, an actively-shielded Agilent Technologies 400-MR DDR2 400 MHz, a Varian Unity Inova 500 MHz, and an actively shielded Varian Unity Inova 600 MHz spectrometer. All spectrometers are housed in the Chemistry/PSBN building. They are dedicated to a wide range of organic and inorganic small molecule and polymer research. And National Institutes of ...

nmr.chem.uiowa.edu nmr.chem.uiowa.edu

University of Iowa NMR Central Research Facility

Sorry, but your browser does not support frames. To get to the first HTML document in the set.

nmr.chem.umn.edu nmr.chem.umn.edu

Chemistry NMR Lab,University of Minnesota

194 and 196 Kolthoff Hall. 207 Pleasant Street S.E. Minneapolis, MN 55455-0431. The NMR (nuclear magnetic resonance) lab is a facility of the chemistry department; its principal job is to provide access to NMR equipment and expertise for departmental research and teaching. It is also available to other departments within the university, other academic institutions, and to external organizations. NMR mission and plans. Information for Industrial Clients:. Instrument and Rate Information.

nmr.chem.uu.nl nmr.chem.uu.nl

NMR Spectroscopy Research Group

JavaScript Menu, DHTML Menu Powered By Milonic. The research of the NMR group aims at gaining fundamental insight into biological processes using solution and solid-state NMR spectroscopy as the main biophysical experimental techniques in combination with molecular biology and computational structural biology methods. Novel research concepts are being developed and applied to complex biomolecular systems including protein-protein and protein-nucleic acid complexes or membrane proteins. Dec 13, 2010.

nmr.chem.uw.edu.pl nmr.chem.uw.edu.pl

Olimpiada Chemiczna

Statistics for day 02-07-2010. Ipfm version: IPFMv0.11.4 - stats for: 02:45:00 - frequency: 0d00:15:00 - interface em0. Stats generated by scr ipfm v. 0.64.

nmr.chem.wsu.edu nmr.chem.wsu.edu

Center for NMR Spectroscopy: Introduction

Center for NMR Spectroscopy. WSU Core Facilities [log in]. Overview of the Console. Running an automated 1H spectrum. 90 degree PW calibration. The WSU Center for NMR Spectroscopy is a central University facility that provides access to state-of-the-art NMR instrumentation. It is administered by the College of Sciences. And its equipment has been funded by grants from the National Institutes of Health. The National Science Foundation. The Battelle Memorial Institute. And the Murdock Charitable Trust.

nmr.chemie.hhu.de nmr.chemie.hhu.de

Universität Düsseldorf: Kernresonanzspektroskopie

Zurück zur Fakultät. Die NMR-Abteilungen an der wissenschaftlichen Einrichtung Chemie. Herzlich Willkommen auf der gemeinsamen Homepage der NMR-Abteilungen der Wissenschaftlichen Einrichtung Chemie (. Diese Abteilungen sind den Instituten für Anorganische und Strukturchemie (. Prof Ch. Janiak) und für Organische Chemie und Makromolekulare Chemie (. Prof T. J. J. Müller. Wir bieten einen gemeinsamen NMR-Service für alle Institute an der Heinrich-Heine-Universität. Herr Behm am Avance DRX 500. Bruker Avanc...

nmr.chemie.uni-koeln.de nmr.chemie.uni-koeln.de

NMR: NMR-Abteilung

News, tips and tricks. News, tips and tricks. Geändert: 20. Dezember 2016. Erstellt: 1. März 2012. Von: N. Schloerer.

nmr.chemistry.manchester.ac.uk nmr.chemistry.manchester.ac.uk

Home | Manchester NMR Methodology Group

Manchester NMR Methodology Group. The NMR methodology group is jointly supervised by Gareth Morris. And currently has 8 members. Concerns the development of novel techniques in high resolution NMR spectroscopy, and their application to problems in chemistry, biochemistry, and medicine. In many cases this work leads to new pulse sequences and software tools, some of which are freely available here. Among current and recent projects in NMR research are work on diffusion-ordered spectroscopy. Material is gr...

nmr.chemistry.ohio-state.edu nmr.chemistry.ohio-state.edu

OSU NMR

The Ohio State University. Department of Chemistry and Biochemistry. New Website - Blog. Please go to the new website/blog. Design from HTML5webtemplates.co.uk. Design downloaded from free website templates.

nmr.chm.jhu.edu nmr.chm.jhu.edu

JHU NMR Core Facility

Welcome to the NMR Facility in the Department of Chemistry at Johns Hopkins University. This facility is valuable resource to the scientific community which assists our users to answer questions to their chemical and biochemical problems. Feel free to email. Dr Joel Tang or visit him in his office if you have any questions, concerns or suggestions. C) Johns Hopkins University.